Installation Guide5 Series Side-By-Side Refrigerator/Freezer
10 Cutout Dimensions9”(22.9 cm)73-3/8”(186.4 cm)82–7/8”(210.5 cm) min.anti-tip board &opening height84–1/16”(213.5 cm) max.anti-tip board &ope
11 Anti-Tip DimensionsTwo 2”x 4” Mounting Boards3” (7.6 cm) x 3-1/2” (8.9 cm)NOTE: If unit is installed deeper than24” (61.0 cm),then shim behind the
12 Cutout Dimensions 48” Side-By-SideStandard Mount24” (61.0 cm)Flush Mount26-3/8” (67.0 cm)9”(22.9 cm)73-3/8”(186.4 cm)82–7/8”(210.5 cm) min.anti
13 Anti-Tip Dimensions 48” Side-By-SideTwo 2”x 4” Mounting Boards3” (7.6 cm) x 3-1/2” (8.9 cm)NOTE: If unit is installed deeper than24” (61.0 cm),
14 Cabinet Information For installation in 24" (61.0 cm) deep cabinets, the door face protrudes 2-3/4” (7.0 cm) from the cabinet face. The handl
15Headline15 Cabinet Information ( with Flush Mount Trim)23-7/8”(60.6 cm)24-5/8”(62.5 cm)26-1/4”(66.7 cm)26-1/2”(67.3 cm)Face of stainless steel door
16Custom Side Panel Dimensions 3/4”(1.9 cm)End panel5/32”(0.4 cm)3/16”(0.5 cm)Back fillerpanel24-5/8”(62.5 cm)24-5/8”(62.5 cm)Optional kickplateNotch
17Custom Side Panel Dimensions ( with Flush Mount Trim)* Depending on how high leveling feet are raised, and cabinet enclosure height.3/4”(1.9 cm)End
18Custom Door Panel Dimensions28-5/16”(71.9 cm)75-1/2”(191.8 cm)3/4”(1.9 cm)18-11/16”(47.5 cm)3/4”(1.9 cm)22-13/16”(57.9 cm)75-1/2”(191.8 cm)3/4”(1.9
19Custom Door Panel Installation32-1/16”(5.2 cm) 2-1/16”(5.2 cm) Back of panelBack of panelFOL bracketFOL bracket“Z” bracket“Z” bracket1-11/16”(4.3 cm
2Table of ContentsWarnings and Important Information _______________________________ 3 Dimensions & Specifi cations (Professional 42” & 48”)___
20Custom Door Panel Installation9x13 Reinstall cabinet trim and screws.78x13x2x2 Slide custom wood panel to the hinge side, ensuring “Z” bracket engag
21Headline 48” Custom Panels21 General Information Area RequirementsVerify the following:• Unit can fi t into residence and can be moved around cor
22Headline22 General Information Water Supply RequirementsUse only 1/4” (6 mm) copper tubing for water line. DO NOT install copper tubing in area whe
23Headline23 General Information Area Requirements • Most of the unit’s weight is at the top. Extra care is needed when moving the unit to pre
24Headline24 Note: If the unit is to be installed fl ush with the cabinets, the fl ush mount side trim must be installed fi rst. If not, skip to “Install
25Headline251278aWall2 x 4RefrigeratorFront of unit21 36 Replace unit top. Replace four side screws. Attach one 2 x 4 to wall stud (refer to dimensio
26Headline2611121314 Pull supply tubing forward under unit.Note: DO NOT use plastic water lines. Flush water line by running two quarts of water into
27Headline2717Make sure evaporator pan is in correct location.15Wall2 x 4RefrigeratorScrew16 Lift unit off rollers to desired height and level unit u
28Headline28Door Stop Adjustment312201221110˚120˚90˚ Open refrigerator door so door stop and shoulder screw are accessible. Note: Shoulder screw shoul
29 Water Filter System Specifi cation and Performance Data Sheet This system has been tested according to NSF/ANSI 42/53 for reduction of the substance
33IMPORTANT – Please Read and Follow! • Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying volta
30 Final Installation Replace the center grille louver.22 Replace top air grille. Using an 8” (20.3 cm) magnetic nut driver, replace the two 1/4” (0.
31 Performance Checklist —Verify cabinet size. — Verify electrical supply and water supply (if applicable). — Install anti-tip device(s) and ve
32Verify Operations Control PanelsSide-by-Side1. Press “ACTIVATE CONTROLS” pad.2. Verify unit is not in Sabbath Mode. If in Sabbath Mode: A.
33Service & Registration If service is required, call your dealer or authorized service agency. The name of the authorized service agency can be o
34Notes_______________________________________________________________________________________________________________________________________________
35Notes_______________________________________________________________________________________________________________________________________________
F21445A EN Viking Range, LLC111 Front StreetGreenwood, Mississippi 38930 USA(662) 455-1200For product information,call 1-888-(845-4641)or visit our we
4IMPORTANT – Please Read and Follow! A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinance
5WARNING TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely inst
6 Dimensions (Side-By-Side)26-1/4”(66.7 cm)41”(104.1 cm)75–15/16”(192.9 cm)3–19/32”(9.1 cm)42”42”42”(106.7 cm)9–5/32”(23.3 cm) 82–3/4”(210.2 cm)min.t
7 Specifi cations (Side-By-Side) 48” Side-By-SideDescription VCSB/CVCSBOverall width 48” (121.9 cm) Overall height (from bottom) 82-3/4” (210.2
8 Dimensions (Flush Mount Trim and Custom Door Overlay) 42” Side-By Side with Flush Mount Trim26-1/4”(66.7 cm)41”(104.1 cm)75–15/16”(192.9 cm)3–19/32
9Specifi cations (Flush Mount Trim and Custom Door Overlay) 48” Side-By-Side Flush Mount Trim and Custom Door OverlayDescription VCSB/CVCSB Flush Mou
Komentarze do niniejszej Instrukcji